Process Details
- Description
- Top Out/Cover Mechanical Inspection
- Folder Number
- 25 108530 00 M
- Folder Details
- 2148 TURNER ROAD SE
- Permit Type
- Mechanical Permit - Commercial
- Scheduled Date
- 6/2/2025
- Assigned Staff
- Inspector Mechanical
Process Comments
Comment Number | Scheduled Date | Comment Date | Staff | Result | Comment |
---|---|---|---|---|---|
1 | 5/29/2025 | Leif Nelson | Corrections | 1. SUPPLY CFM ABILTY OF BATH EXHAUST FANS TO VERIFY VENT LENGTH ABILITY 2. DRYER VENT EXCEEDS 35' .. INSTALL DRYER DUCT VENTILATOR PER OMSC 504.5 3. INSTALL NAIL PLATES AT PLATE PENETRATIONS OF EXHAUST FAN DUCTING PER OMSC 603 4. TRUNK LINE DUCTS DO NOT HAVE VENTILATION HOLES CUT IN PER PLAN 5. ENSURE SHUTOFF VALVE AT INSERT PER LISTING 6. 2ND STORY MECH INCOMPLETE PER PLAN | |
2 | 6/2/2025 | Leif Nelson | Inspected | 1. INSTALL NAIL PLATES AT VENT PLATE PENETRATIONS 2. COMPLETE MECHANICAL FURNACE, W/H ETC AT 2ND FLOOR ... APPROVED 1ST FLOOR |