Process Details

Description
Framing Inspection
Folder Number
24 103723 00 DW
Folder Details
2605 LAUREL AVENUE NE
Permit Type
Dwelling Permit - Triplex/Quadplex
Scheduled Date
1/21/2025
Completed Date
1/21/2025
Assigned Staff
Ricardo Bojorquez

Process Comments

Comment Number Scheduled Date Comment Date Staff Result Comment
1 1/7/2025 Ricardo Bojorquez Corrections ORSC 109.3 Provide electrical, plumbing, and mechanical rough approvals prior to framing inspection. Provide permits for each unit. Verify electrical box separation at 2 hour rated fire wall. Not a complete inspection.
2 1/10/2025 Scott Morse Corrections R109.3 Please ensure completion and approval of MEP's before scheduling Framing inspection.
3 1/13/2025 Ricardo Bojorquez Corrections ORSC 109.3 Previous corrections not made. Provide Mechanical and Plumbing rough inspections prior to framing inspection.
4 1/14/2025 Ricardo Bojorquez Corrections ORSC R302.4.2.1 Per figure 302.4.2.1 Electrical outlets in 2 hour firewalls are required to be offset minimum 24". (laundry rooms O.K.) ORSC 106.4 Maintain 1" airgap at truss assembly. Recall for Fire separation inspections prior to insulation of fire walls. ORSC 109.3 Complete exterior overhang framing prior to full framing approval
5 1/16/2025 Ricardo Bojorquez Corrections Previous corrections not made
6 1/21/2025 Ricardo Bojorquez Approved NOTE: Fire separation (rock wool) in 2 hour wall approved. Recall for insulation prior to sheetrock inspection.