Process Details
- Description
- Underfloor Framing Inspection
- Folder Number
- 23 121835 00 BP
- Folder Details
- 835 COMMERCIAL STREET SE
- Permit Type
- Building Permit - Commercial
- Scheduled Date
- 5/14/2025
- Completed Date
- 5/14/2025
- Assigned Staff
- Inspector Structural
Process Comments
Comment Number | Scheduled Date | Comment Date | Staff | Result | Comment |
---|---|---|---|---|---|
1 | 3/12/2025 | Leif Nelson | Corrections | VERIFIED ON GOING 2ND FLOOR DECKING .... DRAG STRAPS TO COME .... ALSO VERFY ADEQUACY OF TOP FLANGE HANGERS CUT TO FIT ON 6 " WALLS | |
2 | 4/23/2025 | Leif Nelson | Inspected | APPROVED FLOOR STRAPS AT 2ND FLOOR ... ALSO VERIFIED EOR'S DETAIL FOR CUT HANGERS | |
3 | 5/14/2025 | Leif Nelson | Approved | APPROVED 3RD FLOOR DECKING AND STRAPS |