1 |
|
10/22/2024 |
Leif Nelson |
Inspected |
VERIFIED WELDS ON TYPE 1 DUCT |
2 |
|
11/12/2024 |
Leif Nelson |
Inspected |
APPROVED SUPPLY AND RETURN DUCTS IN SHAFTS ... ALSO TRUNK LINES IN CORRIDORS FOR INSUL COVER |
3 |
|
11/18/2024 |
Matthew Smith |
Inspected |
LEVEL 2 UNITS - VERFIY LENGTH OF DRYER DUCTS AND RANGE EXHAUST NOT OVER LENGTH - MAY REQUIRE IN LINE FANS ON DUCTS WITH MORE THE 3 90' BENDS AND OVER 30' IN LENGTH |
4 |
|
11/21/2024 |
Leif Nelson |
Inspected |
VERIFIED MAJORITY OF DUCT WRAP ON TYPE 1 DUCT ... FINAL APPROVAL TO BE COMPLETED WHEN DUCT IS COMPLETE IN SHAFT |
5 |
|
11/26/2024 |
Leif Nelson |
Inspected |
APPROVED TYPE 1 AND MAKE UP AIR DUCTING IN SHAFTS |
6 |
|
12/3/2024 |
Leif Nelson |
Corrections |
PROVIDE SPECS FOR VENT LENGTH OF STOVE HOODS 2. INSTALL LISTED FAN ASSISTS AT DRYER DUCTS EXCEEDING 35 FT W/ BENDS PER OMSC 504.9.1
3. PROVIDE SPECS FOR EXHAUST VENT FROM CASSETTE LENGTH MAXIMUMS |
7 |
|
12/10/2024 |
Leif Nelson |
Inspected |
APPROVED MECH AT 2ND FLOOR UNITS WITH EXTENDED VENT DRYERS PER SUBMITALS |
8 |
|
12/12/2024 |
Leif Nelson |
Inspected |
APPROVED MECH ABOVE LIDS AT 3RD FLOOR WITH DRYERS THAT ARE SPECIFIED DUE TO LONG LENGTHS OF DUCTS |
9 |
|
12/16/2024 |
Leif Nelson |
Inspected |
APPROVED 4TFH FLOOR MECH |
10 |
|
12/18/2024 |
Leif Nelson |
Inspected |
APPROVED 1ST FLR UNITS AND LEASE OFFICE ABOVE LIDS |
11 |
|
1/30/2025 |
Leif Nelson |
Inspected |
APPROVED FRESH AIR DUCTING AT FUTURE T I SPACES |
12 |
|
4/23/2025 |
Leif Nelson |
Inspected |
APPROVED MECHANICAL AT SALES OFFICES EXCEPT BATHROOM ...ALSO APPROVED FLOORS 2-4 UNIT HOOD EXHAUST CONNCTIONS |