Process Details

Description
Grout/Rebar Inspection
Folder Number
22 111605 00 BP
Folder Details
4678 TRUAX DRIVE SE
Permit Type
Building Permit - Commercial
Scheduled Date
5/26/2023
Assigned Staff
Inspector Structural

Process Comments

Comment Number Scheduled Date Comment Date Staff Result Comment
1 1/20/2023 Leif Nelson Inspected REMOVE STANDING WATER ... THEN APPROVED INTERIOR PAD FTGS
2 2/2/2023 Leif Nelson Inspected 1. MAINTAIN REQUIRED CLEARANCES TO REBAR AND REMOVE MUD OFF REBAR AT INDICATED AREAS ... THE APPROVED NORTH,EAST AND WEST EXTERIOR PIERS
3 3/6/2023 Leif Nelson Inspected COMPLETE SLAB POUR BACK DOWELS PER PLAN ... THEN APPROVED NORTHERN 1/3 SOG
4 3/15/2023 Leif Nelson Inspected 1. COMPLETE REMAINING SLAB BARS PER PLAN ... THEN APPROVED REMAINING SOG
5 4/3/2023 Leif Nelson Inspected APPROVED FIRST INDICATED 14 TILT PANELS ... ALSO APPROVED TILT PANELS FOR 2 TRASH ENCLOSURES
6 4/7/2023 Leif Nelson Inspected approved next 13 tilt panels
7 4/10/2023 Leif Nelson Inspected 1. COMPLETE SLAB DOWEL INSTALLS PER PLAN ... THEN APPROVED NEXT 7 PANELS
8 4/12/2023 Leif Nelson Inspected APPROVED REMAINING PANELS
9 4/14/2023 Leif Nelson Inspected APPROVED REMAINING STRIP AND PAD FTGS
10 5/18/2023 Leif Nelson Inspected 1. MAINTAIN MINIMUM 2" COVERAGE ON TOP BARS PER PLAN ... THEN APPROVED TRASH ENCLOSURE FTGS
11 5/24/2023 Leif Nelson Inspected 1. COMPLETE EPOXY DOWELS PER PLAN ... DO NOT POUR UNTIL REQD. 24 HR CURE TIME FOR EPOXY PER LISTING ...THEN OK TO POUR SOUTH AND EAST SIDES
12 5/26/2023 Leif Nelson Inspected APPROVED REMAINING POUR BACK STRIP