Process Details

Description
Fire Comments
Folder Number
21 107584 00 LD
Folder Details
255 CORDON ROAD NE
Permit Type
Land Division - NO LONGER USED - Subdivision
Scheduled Date
6/25/2021
Completed Date
6/28/2021
Assigned Staff
Fire Marshal

Process Comments

Comment Number Scheduled Date Comment Date Staff Result Comment
1 6/28/2021 Sean Mansfield Complete no portion of phase of the development may exceed 30 dwelling units unless the development is protected with approved fire sprinklers or two approved means of fire department access are provided. fire department access is required within 150 feet or all portions of the structure. Dead end roads exceeding 150 feet of fire department access require an approved turn around. fire hydrants shall be located within 600 feet of all portions of the dwellings. all measurements are made along an approved route.