Process Details

Description
Fire Comments
Folder Number
18 124472 00 LD
Folder Details
255 CORDON ROAD NE
Permit Type
Land Division - NO LONGER USED - Subdivision
Scheduled Date
8/29/2019
Completed Date
9/9/2019
Assigned Staff
Fire Marshal

Process Comments

Comment Number Scheduled Date Comment Date Staff Result Comment
1 9/9/2019 Sean Mansfield Complete Approved fire department access will be required for each phase of construction. Only 30 dwelling units may be served from 1 fire department access unless all units have fire sprinklers. Note: the second approved means of fire department access needs to be separated by 1/2 of the diagonal of the development. Dead end roads over 150 feet in length need an approved turnaround. Fire hydrants are required to be provided within 600 feet of all portions of the exterior of the structure. All measurements are made along an approved route.