Development Permit Details
24 122455 00 CO
Permit- Number
- 24 122455 00 CO
- Type
- Commercial Permit - DS - Commercial - New
- Status
- Permit Issued
- Details
- 3980 AIRWAY DRIVE SE
- Description
- New airplane hanger, 8000 sf with associated site work.
Person Details
ANDREW SIEGMUND
- Roles
- Contact, Paid By
- Address
-
PO BOX 840
STAYTON OR 97383
SIEGMUND EXCAVATION
- Roles
- Contractor
- Address
-
PO BOX 840
STAYTON OR 97383-0840
GENE BOLANTE
- Roles
- Designer, Applicant, Contact
- Address
-
PO BOX 5456
SALEM OR 97301
DON LULAY HOMES INC
- Roles
- Responsible Utility Billing Contact, Owner, Paid By
- Address
-
2055 MISSION ST SE
SALEM OR 97302-1225
ASHLEY SMITHSON
- Roles
- Contact
- Address
-
2545 SUMMER ST SE
SALEM OR 97302
Property Details
Info
- In Urban Service Area?
- No
- County Name
- Marion
- Subject to SDF?
- Yes
- Permits Required?
- Yes
- Proposed Developed Area
- .4
- Jurisdiction
- Salem
- Special Conditions
- Contractor to follow all State and Federal Regulations. Private Plumbing Permits are required for all on-site utility installation (Please contact Building & Safety 503-588-6256).
- Water Service Level
- G0
- USGS Elevation
- 210
- PSI
- 53
- Install Domestic Water Meter?
- New
- Install Domestic Water Service Line
- No
- Domestic Water Meter Type
- Disk
- Domestic Water Service Line Size
- 1-inch
- Domestic Water Meter Size
- 3/4-inch
- Geo Review Req'd?
- No
- Erosion Control Permit Req'd?
- City Permit
- Adjacent to Waterway/Wetlands?
- No
- Excavation/Fill Permit Req'd
- No
- Install Irrigation Water Meter?
- No
- Irrigation Water Meter Type
- Disk
- Driveway Req'd
- None
- Driveway Location
- AIRWAY DR
- Driveway #2 Req'd
- None
- Driveway Closure Req'd
- No
- Driveway #2 Closure Req'd
- No
- Sidewalk Req'd?
- None
- Sidewalk Width
- 5
- Sidewalk Street Name
- AIRWAY DR
- Sidewalk #2 Req'd?
- None
- Lane Closure Required
- None
- Storm?
- Connect
- Length of Storm Pipe
- 20
- Storm Location
- existing stub, 5' north of sewer stub
- Storm Disconnect
- No
- Street Opening Required?
- No
- Storm Tap Type
- None
- Sewer Tap Type
- None
- Sewer?
- Connection - Inside City
- Length of Sewer Pipe
- 20
- Sewer Location
- Contractor to expose existing sewer stub & call for Public Works inspection to verify condition
- Is Floodplain Development Required?
- N/A
- Elevation Certificate Req'd?
- No
- Latitude/Longitude
- Null
- Horizontal Datum
- NAD 1927
- NFIP Community Name & Community Number
- Salem, City of & 410167
- State
- Oregon
- Firm Index Date
- 1/2/2003
- Base Flood Elevation Source
- FIRM
- Elevation Datum
- NGVD 1929
- Is this CBRS or OPA?
- No
- ROW Dedication Req'd?
- No
- Commercial Vehicle Trips
- 4
- New Impervious Area (sq ft)
- 13670
Action Details
Final B&S Inspections
-
Regulatory Final
- Status:
- Open
- Assigned Staff:
- PW Coordinator
Info
Plan Review
-
DS Plan Review
- Status:
- Approved
- Completed Date:
- 2/28/2025
- Assigned Staff:
- Zach Diehl
- View Details
-
PW Make Ready To Issue
- Status:
- Ready to Issue
- Completed Date:
- 2/28/2025
- Assigned Staff:
- PW Coordinator
- View Details
Info
PW Finals
-
Final Field Inspection
- Status:
- Open
- Assigned Staff:
- PW Inspector
Info
PW Inspections
-
Sewer/Storm Cross-Connect Inspection
- Status:
- Open
- Assigned Staff:
- PW Inspector
-
Sewer Inspection
- Status:
- Open
- Assigned Staff:
- PW Inspector
-
Storm Inspection
- Status:
- Open
- Assigned Staff:
- PW Inspector
-
Erosion Control Inspection
- Status:
- Inactive
- Assigned Staff:
- PW Inspector
- View Details
Info
PW Water Inspections
-
Meter Installation
- Status:
- Complete
- Completed Date:
- 7/25/2025
- Assigned Staff:
- Greg Presser
- View Details
Info
PW Water Quality & Treatment Inspections
-
PW Backflow Device Inspection
- Status:
- Open
- Assigned Staff:
- Scott Ruyle
Info