Development Permit Details
22 115137 00 CO
- Number
- 22 115137 00 CO
- Type
- Commercial Permit - DS - Commercial - New
- Status
- Completed
- Details
- CO - DAVES HOT CHICKEN & JERSEY MIKES - 3815 CENTER STREET NE
- Description
- (CIVIL SITE WORK ONLY) TWO RESTAURANT BUILDINGS, A DRIVE-THROUGH, PEDESTRIAN CONNECTIONS, PARKING LOT AND LANDSCAPING MODIFICATIONS
Person Details
DOWL
- Roles
- Paid By, Engineer, Applicant
- Address
-
309 SW 6TH AV STE 750
PORTLAND OR 97204
ALEX KARCHER
- Roles
- Responsible Utility Billing Contact, Contact
- Address
-
875 COUNTRY CLUB RD
EUGENE OR 97401
PAM PRISER
- Roles
- Contact, Paid By
- Address
-
875 COUNTRY CLUB RD
EUGENE OR 97401
MIKE TOWLE
- Roles
- Contact
- Address
-
720 SW WASHINGTON ST STE 750
PORTLAND OR 97205
GREG WADZINSKI
- Roles
- Paid By, Designer
- Address
-
720 SW WASHINGTON ST STE 750
PORTLAND OR 97205
SETH GAREY
- Roles
- Owner
- Address
-
1701 SE COLUMBIA RIVER DR
VANCOUVER WA 98661-8078
Property Details
Info
- In Urban Service Area?
- Yes
- County Name
- Marion
- Subject to SDF?
- Yes
- Permits Required?
- Yes
- Proposed Developed Area
- .81
- Jurisdiction
- Salem
- Special Conditions
- Contractor to follow all State and Federal Regulations. Private Plumbing Permits are required for all on-site utility installation (Please contact Building & Safety 503-588-6256). Any work performed within Public Right-of-Way requires a separate "Work In ROW" permit (Please contact Ron Adkins or Van Tran at 503-588-6211).
- Water Service Level
- G0
- USGS Elevation
- 210
- PSI
- 53
- Install Domestic Water Meter?
- New
- Install Domestic Water Service Line
- No
- Domestic Water Meter Type
- Disk
- Domestic Water Service Line Size
- 2-inch
- Domestic Water Meter Size
- 1.5-inch
- Geo Review Req'd?
- No
- Erosion Control Permit Req'd?
- City Permit
- Adjacent to Waterway/Wetlands?
- No
- Excavation/Fill Permit Req'd
- No
- Install Irrigation Water Meter?
- No
- Install Irrigation Water Service Line
- No
- Driveway Req'd
- New
- Driveway Width
- 75
- Driveway Location
- CENTER ST - Replace existing driveway along Center Street NE east of the proposed development area. See plans for location and details.
- Driveway #2 Req'd
- None
- Driveway Closure Req'd
- No
- Driveway #2 Closure Req'd
- No
- Sidewalk Req'd?
- New
- Sidewalk Width
- 15
- Sidewalk Length
- 250
- Sidewalk Street Name
- CENTER ST - Remove/replace and widen existing sidewalk along the Center Street NE frontage of the development area and along the replaced driveway on Center Street NE. Extend sidewalk improvements to expansion joint (west) and cold mix joint (east) of the development frontage.
- Sidewalk Location
- Curb Line
- Sidewalk #2 Req'd?
- None
- Lane Closure Required
- None
- Storm?
- Connect
- Length of Storm Pipe
- 0
- Storm Location
- Public storm connection installed part of 22-112408-PC. GSI facilities on-site constructed with this permit.
- Storm Disconnect
- No
- Street Opening Required?
- No
- Storm Tap Type
- None
- Sewer Tap Type
- None
- Sewer?
- Connection - Inside City
- Length of Sewer Pipe
- 0
- Sewer Location
- 6-inch SS lateral installed part of 22-112408-PC
- Is Floodplain Development Required?
- N/A
- Elevation Certificate Req'd?
- No
- Latitude/Longitude
- Null
- Horizontal Datum
- NAD 1927
- NFIP Community Name & Community Number
- Salem, City of & 410167
- State
- Oregon
- Firm Index Date
- 1/2/2003
- Base Flood Elevation Source
- FIRM
- Elevation Datum
- NGVD 1929
- Is this CBRS or OPA?
- No
- ROW Dedication Req'd?
- Yes
- ROW Dedication Description
- 48-feet from centerline on Center Street NE
- Commercial Vehicle Trips
- 0
- New Impervious Area (sq ft)
- 0
Action Details
Agreements
-
ROW Dedication
- Status:
- Approved
- Completed Date:
- 6/16/2023
- Assigned Staff:
- Matt Olney
- View Details
-
PSFA
- Status:
- Approved
- Completed Date:
- 6/16/2023
- Assigned Staff:
- Matt Olney
- View Details
Info
Application Intake
-
Assign Bin Number
- Status:
- Open
- Assigned Staff:
- PW Coordinator
Info
Final B&S Inspections
-
Regulatory Final
- Status:
- Approved
- Completed Date:
- 7/18/2023
- Assigned Staff:
- Matt Olney
- View Details
Info
Plan Review
-
DS Plan Review
- Status:
- Approved
- Completed Date:
- 10/19/2022
- Assigned Staff:
- Matt Olney
- View Details
-
PW Make Ready To Issue
- Status:
- Ready to Issue
- Completed Date:
- 10/19/2022
- Assigned Staff:
- PW Coordinator
- View Details
Info
PW Environmental Services
-
Environmental Services Inspection
- Status:
- Approved
- Completed Date:
- 4/27/2023
- Assigned Staff:
- Environmental Services
- View Details
Info
PW Finals
-
Final Field Inspection
- Status:
- Approved
- Completed Date:
- 7/5/2023
- Assigned Staff:
- PW Inspector
- View Details
Info
PW Inspections
-
Driveway Inspection
- Status:
- Approved
- Completed Date:
- 4/26/2023
- Assigned Staff:
- PW Inspector
- View Details
-
Sidewalk Inspection
- Status:
- Approved
- Completed Date:
- 4/26/2023
- Assigned Staff:
- PW Inspector
- View Details
-
Erosion Control Inspection
- Status:
- Approved
- Completed Date:
- 4/26/2023
- Assigned Staff:
- PW Inspector
- View Details
-
Detention Inspection
- Status:
- Approved
- Completed Date:
- 4/26/2023
- Assigned Staff:
- PW Inspector
- View Details
-
Sewer Inspection
- Status:
- Approved
- Completed Date:
- 4/26/2023
- Assigned Staff:
- PW Inspector
- View Details
-
Storm Inspection
- Status:
- Approved
- Completed Date:
- 4/26/2023
- Assigned Staff:
- PW Inspector
- View Details
-
Street Trees
- Status:
- Closed
- Completed Date:
- 3/23/2023
- Assigned Staff:
- PW Inspector
- View Details
Info
PW Water Inspections
-
Meter Installation
- Status:
- Complete
- Completed Date:
- 12/29/2022
- Assigned Staff:
- Greg Presser
- View Details
Info
PW Water Quality & Treatment Inspections
-
PW Backflow Device Inspection
- Status:
- Approved
- Completed Date:
- 6/2/2023
- Assigned Staff:
- Scott Ruyle
- View Details
Info