Process Details
- Description
- Framing Inspection
- Folder Number
- 25 107715 00 BP
- Folder Details
- 2801 19TH STREET SE
- Permit Type
- Building Permit - Commercial
- Scheduled Date
- 7/16/2025
- Assigned Staff
- Inspector Structural
Process Comments
Comment Number | Scheduled Date | Comment Date | Staff | Result | Comment |
---|---|---|---|---|---|
1 | 7/16/2025 | Leif Nelson | Inspected | APPROVED EXTERIOR PLY FOR COVER... 1. INSTALL ADDITIONAL KING STUDS AT WINDOW PER PLAN 2. PLANS CALL FOR 2 HR WALL AT INFILL, WILL NEED TO VERIFY AND OR REVISE WINDOW REQS. 3. TIGHTEN HD NUTS ALL PER LISTING 4. SUPPLY SPECIAL INSPECTION REPORT FOR EPOXIED ANCHORS FOR HD'S PER PLAN |